Microtest 6630
362376
Microtest 6630 Impedance Analyzer
Microtest 6630 Impedance Analyzer
0.00

Product Description:

The test frequency of the 6630 Precision Impedance Analyzer is DC 10Hz-30MHz and the test sigal is 10mV-2Vrms (min. resolution 1mV), and is suitable for the LCR and DCR testes of AC signals. The measurement in a continuously changing environment can be executed stage-by-stage with the test frequency and grade, and high-speed continuous tests can be performed under different test and mode conditions. The machine also supports LAN, USB and GPIB PC connection capabilities to improve the design and test efficiency significantly. MICROTEST 6630 Impedance Analyzer also provides fixtures for material dielectric permittivity measurement that allows PCB designed engineers to reduce the faulty conditions with the comprehensive information of permittivity while designing PCB layouts.

  • Signal source frequency range: DC 10Hz ~ 3/5/10/20/30MHz
  • Signal source grade: 10mV ~ 2V / 200μA ~ 20mA
  • Basic accuracy up to ±0.08%
  • ALC function
  • Output resistance 25Ω/100Ω, switchable
  • Wide resistance measurement range from 25 mΩ to 40 MΩ (measurement accuracy up to 10%)
  • Parameters: |Z|, |Y|, θ, R, X, G, B, L, C, D, Q, DCR, ESR, Vac, Iac, Vdc and Idc
  • Ultra-high measuring speed <3ms
  • Open circuit/short circuit/load calibration function
  • Electric meter mode, multistep list mode, scan & analyze mode
  • Up to four component parameters can be selected in the electric meter mode. The induction and DCR values can be measured and displayed simultaneously
  • Auto component classification: Comparator function and Handler BIN classification function
  • Up to 50 sets of multistep list programs can be stored in the permanent memory and up to 15 test steps can be arranged in each program
  • Rapid automation and data access function is realizable for USB, LAN, GPIB and RS232 interfaces
  • PC connection data analysis software is available optionally
  • 7″ 800*640 TFT LCD color screen
  • Ultra-light design: 365*145* 360mm, 3kg
  • Ultra-low power consumption (<30W) without fans and zero noise

Product Specification:

Specification

   
 

 

 

 

Test Frequency

6630-03,6330-03G 10Hz ~ 3MHz
6630-05,6330-05G 10Hz ~ 5MHz
6630-10,6330-10G 10Hz ~ 10MHz
6630-20,6330-20G 10Hz ~ 20MHz
6630-30,6330-30G 10Hz ~ 30MHz
Minimum Resolution 100mHz, 6-bit Frequency Input
Accuracy ± 0.01
Basic Accuracy ± 0.08%
 

 

 

 

AC Measurement

Test Signal Voltage Level  10mV  2Vrms
Voltage Minimum Resolution 1mV
Accuracy ALC ON:6% Voltage ± 2mV
ALC OFF
:10% * Voltage ± 2mV
Test Signal Current Level 200µA – 20mArms
Current Minimum Resolution 10µA
Accuracy ALC ON:6% Current ± 20µA
ALC OFF
:10% * Current ± 20µA
Test Time  (The fastest) < 3mS
Output Impedance 25Ω/100Ω, switchable (Nominal value)
Parameters |Z||Y|、θ、XRGBLDQDCRC、 Vdc-IdcESR
Measurement Mode Meter mode, Graphic scanning*, Multi-steps mode

 

Marked with* graphic scanning function only applies to G series model

Calibration Open Circuit/ Short Circuit/Load Calibration
Measurement Circuit Series/Parallel
Multi-steps Mode 50 groups of Multi-steps setting (Each group contains up to 15 steps)
PC LINK / CPK Option
Flash Memory Built-in flash for setting 100 set documents
USB LCR setting documents, BMP graphics, Test result data
 

 

Interface

 

I/O Interface Handler
Serial Interface USB、RS232
Parallel Interface GPIB
Display 7.0”TFT, 800×480 Color Screen
Environment Temperature: 10℃ ~ 40℃   Humidity: 90%
Power Supply Voltage 90V  264Vac
Frequency 47Hz ~ 63Hz
Power Consumption Low power consumption: Maximum 30W (Nominal value)
Dimension (W*H*D) 344x145x343 mm
Weight 3 kg

Parameters Measurement Ranges

   
|Z|, R, X ± 0.000m to 999.999M
|Y| G B ± 0.00000μS to 999.999kS
DCR 0.00mΩ to 100MΩ
C ± 0.00000pF to 999.999F
L ± 0.00nH to 999.999kH
D ± 0.00000 to 9.99999
Q ± 0.00 to 999999
θ ± 0.000° to 180.000°
Δ% ± 0.000% to 999.999%

Applications

   
Dielectric Material Estimation on permittivity and consumption tangent of plastic, ceramic and PCB
Passive Components Capacitor, Inductor, Resistor, Transformer, Ceramic resonator
Semiconductor Components The CV characteristics analysis of varactor diodes, Diodes
Other Components Estimation of the impedance of PCB components
Electromagnetic Material
  • Açıklama
    • Product Description:

      The test frequency of the 6630 Precision Impedance Analyzer is DC 10Hz-30MHz and the test sigal is 10mV-2Vrms (min. resolution 1mV), and is suitable for the LCR and DCR testes of AC signals. The measurement in a continuously changing environment can be executed stage-by-stage with the test frequency and grade, and high-speed continuous tests can be performed under different test and mode conditions. The machine also supports LAN, USB and GPIB PC connection capabilities to improve the design and test efficiency significantly. MICROTEST 6630 Impedance Analyzer also provides fixtures for material dielectric permittivity measurement that allows PCB designed engineers to reduce the faulty conditions with the comprehensive information of permittivity while designing PCB layouts.

      • Signal source frequency range: DC 10Hz ~ 3/5/10/20/30MHz
      • Signal source grade: 10mV ~ 2V / 200μA ~ 20mA
      • Basic accuracy up to ±0.08%
      • ALC function
      • Output resistance 25Ω/100Ω, switchable
      • Wide resistance measurement range from 25 mΩ to 40 MΩ (measurement accuracy up to 10%)
      • Parameters: |Z|, |Y|, θ, R, X, G, B, L, C, D, Q, DCR, ESR, Vac, Iac, Vdc and Idc
      • Ultra-high measuring speed <3ms
      • Open circuit/short circuit/load calibration function
      • Electric meter mode, multistep list mode, scan & analyze mode
      • Up to four component parameters can be selected in the electric meter mode. The induction and DCR values can be measured and displayed simultaneously
      • Auto component classification: Comparator function and Handler BIN classification function
      • Up to 50 sets of multistep list programs can be stored in the permanent memory and up to 15 test steps can be arranged in each program
      • Rapid automation and data access function is realizable for USB, LAN, GPIB and RS232 interfaces
      • PC connection data analysis software is available optionally
      • 7″ 800*640 TFT LCD color screen
      • Ultra-light design: 365*145* 360mm, 3kg
      • Ultra-low power consumption (<30W) without fans and zero noise

      Product Specification:

      Specification

         
       

       

       

       

      Test Frequency

      6630-03,6330-03G 10Hz ~ 3MHz
      6630-05,6330-05G 10Hz ~ 5MHz
      6630-10,6330-10G 10Hz ~ 10MHz
      6630-20,6330-20G 10Hz ~ 20MHz
      6630-30,6330-30G 10Hz ~ 30MHz
      Minimum Resolution 100mHz, 6-bit Frequency Input
      Accuracy ± 0.01
      Basic Accuracy ± 0.08%
       

       

       

       

      AC Measurement

      Test Signal Voltage Level  10mV  2Vrms
      Voltage Minimum Resolution 1mV
      Accuracy ALC ON:6% Voltage ± 2mV
      ALC OFF
      :10% * Voltage ± 2mV
      Test Signal Current Level 200µA – 20mArms
      Current Minimum Resolution 10µA
      Accuracy ALC ON:6% Current ± 20µA
      ALC OFF
      :10% * Current ± 20µA
      Test Time  (The fastest) < 3mS
      Output Impedance 25Ω/100Ω, switchable (Nominal value)
      Parameters |Z||Y|、θ、XRGBLDQDCRC、 Vdc-IdcESR
      Measurement Mode Meter mode, Graphic scanning*, Multi-steps mode

       

      Marked with* graphic scanning function only applies to G series model

      Calibration Open Circuit/ Short Circuit/Load Calibration
      Measurement Circuit Series/Parallel
      Multi-steps Mode 50 groups of Multi-steps setting (Each group contains up to 15 steps)
      PC LINK / CPK Option
      Flash Memory Built-in flash for setting 100 set documents
      USB LCR setting documents, BMP graphics, Test result data
       

       

      Interface

       

      I/O Interface Handler
      Serial Interface USB、RS232
      Parallel Interface GPIB
      Display 7.0”TFT, 800×480 Color Screen
      Environment Temperature: 10℃ ~ 40℃   Humidity: 90%
      Power Supply Voltage 90V  264Vac
      Frequency 47Hz ~ 63Hz
      Power Consumption Low power consumption: Maximum 30W (Nominal value)
      Dimension (W*H*D) 344x145x343 mm
      Weight 3 kg

      Parameters Measurement Ranges

         
      |Z|, R, X ± 0.000m to 999.999M
      |Y| G B ± 0.00000μS to 999.999kS
      DCR 0.00mΩ to 100MΩ
      C ± 0.00000pF to 999.999F
      L ± 0.00nH to 999.999kH
      D ± 0.00000 to 9.99999
      Q ± 0.00 to 999999
      θ ± 0.000° to 180.000°
      Δ% ± 0.000% to 999.999%

      Applications

         
      Dielectric Material Estimation on permittivity and consumption tangent of plastic, ceramic and PCB
      Passive Components Capacitor, Inductor, Resistor, Transformer, Ceramic resonator
      Semiconductor Components The CV characteristics analysis of varactor diodes, Diodes
      Other Components Estimation of the impedance of PCB components
      Electromagnetic Material
Kapat