Product Description:
The 6379 LCR Meter that is provided with high accuracy and speed. It is a cost and multiple- function utility and is able to perform the component test entirely. 6379 can collocate with DC Bias. The friendly operation interface design is in synchronization with the international trend and easy to operate to import into the production lines quickly. Synchronous tests with multiple parameter settings. Because of the high-precision values of measured data and superior efficacy, it must be a necessary testing instrument of components and materials. It supports the interfaces of RS232, LAN, USB and GPIB PC connections.
Product Specification:
Measurement Data
Test Frequency | 20Hz-10MHz |
Points Of Test Frequency | Continuity |
Basic Accuracy | ± 0.1% |
AC Drive Level | 10mV to 2Vrms (1m Vrms steps) |
DC Drive Level | 0.01V~2V |
Output Impedance | 100Ω |
Frequency trimming resolution | 5 Digits |
Frequency output accuracy | ± 0.01% |
AC test speed (Max.) | 75mS |
AC test speed (Fast) | 150mS |
AC test speed (Medium) | 450mS |
AC test speed (Slow) | 600mS |
DC test speed (Max.) | 30mS |
DC test speed (Fast) | 60mS |
DC test speed (Medium) | 120mS |
DC test speed (Slow) | 500mS |
DC Bias Current Source | Option (Model 6220) |
Specifications
Measured Value Detection Mode | Define upper and lower thresholds according to main and sub parameters |
ESR | Series/Parallel |
Mathematical Mode | Absolute/Percentage |
Test Range | Automatic/Lock |
Indicator | Pass/Fail/Bias LED and Built-in speaker |
Output Terminal | BNC connector |
Safety | EN61010-1 |
Immunity | EN61326-1 |
Emissions | EN55022 Class A |
Calibration | Open Circuit / Short Circuit: Avoid the misreading caused by the stray capacitance from kelvin clips and fixtures |
Auto-save when power-off function | When the power is turned off or encounter a power outage, all the data will be saved automatically and recovered when tester system is switched on again |
Power Supply | Voltage 90-132Vac or 198-264Vac (selectable) |
Frequency 47-63Hz | |
Display | 320*240 dot-matrix display |
Interface | RS-232, GPIB (option), Handler (option) |
Flash Memory | Built-in SDRAM for storage of 64 groups of Multi-steps setting (Each group contains up to 30 steps) |
Operation | Auto、Manual、RS-232、GPIB (option)、Handler (option) |
Environment | Temperature : 10°C to 40°C Humidity : 20 ~ 90% |
Dimension (W*H*D) | 340x133x525 mm |
Weight | 9 Kg |
Parameters Measurement Ranges
|Z| R X | 0.1 mΩ – 100MΩ |
|Y| G B | 10nS – 1000S |
Cs Cp | 0.01pF – >1F |
Ls Lp | 0.01nH – 100KH |
D | 0.00001 – 9.9999 |
Q | 0.1 – 9999.9 |
DCR | 0.1mΩ – 100MΩ |
Δ% | -999.99% – 999.99% |
Θ | -180° – +180° |
Applications
Resistance, Capacitance, Inductance, Oscillators, Sensors, Delay Line, Filters, Resonators
- Açıklama
Product Description:
The 6379 LCR Meter that is provided with high accuracy and speed. It is a cost and multiple- function utility and is able to perform the component test entirely. 6379 can collocate with DC Bias. The friendly operation interface design is in synchronization with the international trend and easy to operate to import into the production lines quickly. Synchronous tests with multiple parameter settings. Because of the high-precision values of measured data and superior efficacy, it must be a necessary testing instrument of components and materials. It supports the interfaces of RS232, LAN, USB and GPIB PC connections.
Product Specification:
Measurement Data
Test Frequency 20Hz-10MHz Points Of Test Frequency Continuity Basic Accuracy ± 0.1% AC Drive Level 10mV to 2Vrms (1m Vrms steps) DC Drive Level 0.01V~2V Output Impedance 100Ω Frequency trimming resolution 5 Digits Frequency output accuracy ± 0.01% AC test speed (Max.) 75mS AC test speed (Fast) 150mS AC test speed (Medium) 450mS AC test speed (Slow) 600mS DC test speed (Max.) 30mS DC test speed (Fast) 60mS DC test speed (Medium) 120mS DC test speed (Slow) 500mS DC Bias Current Source Option (Model 6220) Specifications
Measured Value Detection Mode Define upper and lower thresholds according to main and sub parameters ESR Series/Parallel Mathematical Mode Absolute/Percentage Test Range Automatic/Lock Indicator Pass/Fail/Bias LED and Built-in speaker Output Terminal BNC connector Safety EN61010-1 Immunity EN61326-1 Emissions EN55022 Class A Calibration Open Circuit / Short Circuit: Avoid the misreading caused by the stray capacitance from kelvin clips and fixtures Auto-save when power-off function When the power is turned off or encounter a power outage, all the data will be saved automatically and recovered when tester system is switched on again Power Supply Voltage 90-132Vac or 198-264Vac (selectable) Frequency 47-63Hz Display 320*240 dot-matrix display Interface RS-232, GPIB (option), Handler (option) Flash Memory Built-in SDRAM for storage of 64 groups of Multi-steps setting (Each group contains up to 30 steps) Operation Auto、Manual、RS-232、GPIB (option)、Handler (option) Environment Temperature : 10°C to 40°C Humidity : 20 ~ 90% Dimension (W*H*D) 340x133x525 mm Weight 9 Kg Parameters Measurement Ranges
|Z| R X 0.1 mΩ – 100MΩ |Y| G B 10nS – 1000S Cs Cp 0.01pF – >1F Ls Lp 0.01nH – 100KH D 0.00001 – 9.9999 Q 0.1 – 9999.9 DCR 0.1mΩ – 100MΩ Δ% -999.99% – 999.99% Θ -180° – +180° Applications
Resistance, Capacitance, Inductance, Oscillators, Sensors, Delay Line, Filters, Resonators