Microtest 5435
362398
Microtest 5435 Transformer Tester
Microtest 5435 Transformer Tester
0.00

Product Description:

5435 transformer tester, test frequency is 20Hz~200kHz, 48 test points. By adopting innovative patent design, this tester is able to meet all your test requirements for multi-pin network communication transformer under the same volume condition. To prevent the fixture interference from affecting measured values during testing, the software has high-frequency compensation function (zero-setting when the fixture encounters Open/Short), which makes the readings from fixture are almost the same as measured values therefore increase the tester credibility. The best choice for transformer testing. The application of the transformer tester includes power transformers and network communication transformers, etc.

  • Basic Accuracy up to 0.1%
  • Support computer software connection and advanced software editing function
  • Support open circuit/ short circuit calibration function
  • Able to test 30 items per second under fastest test speed. Elevate productivity significantly through auto-scan function
  • Paired with a 48-pin fixture to meet the test requirements for multi-pin network communication transformer
  • Optional 8mA DC Bias / 5×38 model is equipped with Meter Mode function / Support USB interface for data storag

Product Specification:

Measured Data

   
Frequency 20Hz-200KHz
Turn Ratio Frequency 50Hz ~ 200kHz (10Vac Max.)
Measurement Parameters Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Resistance (ACR)、Quality Factor (Q)、Phase angle(Ø)、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit
Basic Accuracy ±0.1% (AC  parameter :  1KHz)
Output Impedance 100Ω
Frequency trimming resolution 5digits
Frequency output accuracy ±0.01%
Point of Test 48 Points
ESR Series/Parallel
Mathematical Mode Absolute/Percentage 
Calibration Open Circuit/ Short Circuit/Load Calibration

Specifications

   
Power Supply Voltage 90Vac ~ 125Vac or 190Vac ~ 250Vac
  Frequency 48Hz ~ 62Hz
Display 320*240 dot-matrix display
Interface RS-232, Handler (option), USB (option)
Flash Memory 60 sets
Operation Auto、Manual、Remote Trigger
Environment Temperature : 10 ~ 40℃     Humidity : 10% ~ 90%
Dimension (W*H*D) 360x133x420 (mm)
Weight 9 (Kg)

Parameters Measurement Ranges

       
Parameter Range Basic Accuracy
(AC  parameter :  1KHz)
 speed
L, LK 0.1nH ~ 9999.99H  0.1%  75ms
C 0.00001pF ~ 999.99mF  0.1%  75ms
Q,D 0.00001 ~ 99999  0.0005  75ms
Z,X,R 0.00001Ω ~ 99.9999MΩ  0.1%  75ms
Y 0.01nS ~ 99.9999S  0.1%  75ms
θ -180°~ +180°  0.03°  75ms
DCR 0.01mΩ ~ 99.999MΩ  0.1%  25ms
Turn 0.01 ~ 99999.99turns  0.5%  75ms
Pin-Short 12 pairs, between pin to pin  —  25ms

Applications

Power transformer, Network communication transformer

  • Açıklama
    • Product Description:

      5435 transformer tester, test frequency is 20Hz~200kHz, 48 test points. By adopting innovative patent design, this tester is able to meet all your test requirements for multi-pin network communication transformer under the same volume condition. To prevent the fixture interference from affecting measured values during testing, the software has high-frequency compensation function (zero-setting when the fixture encounters Open/Short), which makes the readings from fixture are almost the same as measured values therefore increase the tester credibility. The best choice for transformer testing. The application of the transformer tester includes power transformers and network communication transformers, etc.

      • Basic Accuracy up to 0.1%
      • Support computer software connection and advanced software editing function
      • Support open circuit/ short circuit calibration function
      • Able to test 30 items per second under fastest test speed. Elevate productivity significantly through auto-scan function
      • Paired with a 48-pin fixture to meet the test requirements for multi-pin network communication transformer
      • Optional 8mA DC Bias / 5×38 model is equipped with Meter Mode function / Support USB interface for data storag

      Product Specification:

      Measured Data

         
      Frequency 20Hz-200KHz
      Turn Ratio Frequency 50Hz ~ 200kHz (10Vac Max.)
      Measurement Parameters Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Resistance (ACR)、Quality Factor (Q)、Phase angle(Ø)、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit
      Basic Accuracy ±0.1% (AC  parameter :  1KHz)
      Output Impedance 100Ω
      Frequency trimming resolution 5digits
      Frequency output accuracy ±0.01%
      Point of Test 48 Points
      ESR Series/Parallel
      Mathematical Mode Absolute/Percentage 
      Calibration Open Circuit/ Short Circuit/Load Calibration

      Specifications

         
      Power Supply Voltage 90Vac ~ 125Vac or 190Vac ~ 250Vac
        Frequency 48Hz ~ 62Hz
      Display 320*240 dot-matrix display
      Interface RS-232, Handler (option), USB (option)
      Flash Memory 60 sets
      Operation Auto、Manual、Remote Trigger
      Environment Temperature : 10 ~ 40℃     Humidity : 10% ~ 90%
      Dimension (W*H*D) 360x133x420 (mm)
      Weight 9 (Kg)

      Parameters Measurement Ranges

             
      Parameter Range Basic Accuracy
      (AC  parameter :  1KHz)
       speed
      L, LK 0.1nH ~ 9999.99H  0.1%  75ms
      C 0.00001pF ~ 999.99mF  0.1%  75ms
      Q,D 0.00001 ~ 99999  0.0005  75ms
      Z,X,R 0.00001Ω ~ 99.9999MΩ  0.1%  75ms
      Y 0.01nS ~ 99.9999S  0.1%  75ms
      θ -180°~ +180°  0.03°  75ms
      DCR 0.01mΩ ~ 99.999MΩ  0.1%  25ms
      Turn 0.01 ~ 99999.99turns  0.5%  75ms
      Pin-Short 12 pairs, between pin to pin  —  25ms