The higher temperature Isotech Blackbody Fixed Point Cells consist of high purity metals within a graphite body. Graphite reacts with air to form Carbon Dioxide. The rate of the reaction is temperature dependant. The effect is small at low temperatures but increases at higher temperatures.

For Indium and Tin cells the effect is small and for Indium, Tin and Zinc cells in general no attention needs to be made. Yet for Aluminium, Silver and Copper Cells the oxygen must be excluded or the cells would be quickly damaged.

The Model 984 Gas Flow System connects between an inert gas supply, such as Argon or Nitrogen and the Cell in its apparatus. The Model 984 has a regulator and a flow meter optimised to easily set the flow to 0.2 L/min and features an audible alarm should the gas flow be interrupted.

Tech Spec

TECHNICAL FEATURE VALUE
Model 984
Input-Output Connectors Genevac 16KF
Alarm Audible
Power 15 Watts
Voltage 12Vdc
Dimensions Height 240mm Width 120mm Depth 220mm (excluding connection pipes)
Weight 2.5kg
How to order Model 984 Gas Flow System: Supplied with external power supply, 2 x connecting pipes and fittings.

Downloads

  • Açıklama
    • Product Description

      The higher temperature Isotech Blackbody Fixed Point Cells consist of high purity metals within a graphite body. Graphite reacts with air to form Carbon Dioxide. The rate of the reaction is temperature dependant. The effect is small at low temperatures but increases at higher temperatures.

      For Indium and Tin cells the effect is small and for Indium, Tin and Zinc cells in general no attention needs to be made. Yet for Aluminium, Silver and Copper Cells the oxygen must be excluded or the cells would be quickly damaged.

      The Model 984 Gas Flow System connects between an inert gas supply, such as Argon or Nitrogen and the Cell in its apparatus. The Model 984 has a regulator and a flow meter optimised to easily set the flow to 0.2 L/min and features an audible alarm should the gas flow be interrupted.

      Tech Spec

      TECHNICAL FEATURE VALUE
      Model 984
      Input-Output Connectors Genevac 16KF
      Alarm Audible
      Power 15 Watts
      Voltage 12Vdc
      Dimensions Height 240mm Width 120mm Depth 220mm (excluding connection pipes)
      Weight 2.5kg
      How to order Model 984 Gas Flow System: Supplied with external power supply, 2 x connecting pipes and fittings.