Product Description:
A precision calibrator designed to provide rapid high accuracy calibration of portable appliance testers and insulation/continuity testers.
The 5080 PAT calibrator has functions for earth bond, insulation, leakage, touch leakage, and load test.
Housed in a robust safety case the 5080 is easily portable and ideal for field calibration work. It is battery powered, which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current.
The 5080 is a dedicated solution for PAT testers and part of the electrical testing calibration range from Time Electronics. Other models include the 5030 electrical tester calibrator for RCD, loop, insulation, earth testers and multifunction installation testers. For insulation testers the 5069 InsCal is a portable instrument with resistance up to 100GOhm, and 10kV operation.
Technical Specification:
EARTH BOND: CALIBRATED LOW VALUE RESISTIVE LOADS |
---|
Values / Accuracy | 20mΩ, accuracy 5% 190mΩ, 210mΩ, 950mΩ, 1.050mΩ, 1.08Ω, 2Ω, 10Ω, 18Ω, accuracy 1% |
Open circuit voltage measurement | Range: 0 to 20V Accuracy: 0.25% of full scale |
High current AC measurement | Range: 0 to 50A AC Accuracy: 0.5% of reading +/- 0.2A |
Low current AC measurement | Range: 0 to 2A AC Accuracy: 0.5% of reading +/- 2mA |
Low current DC measurement | Range: 0 to 2A DC Accuracy: 1% of reading +/- 2mA |
INSULATION: CALIBRATED HIGH VALUE RESISTIVE LOADS |
---|
Values / Accuracy | 95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ, accuracy 0.1% 20MΩ, 50MΩ, 100MΩ, accuracy 1.0% |
Open circuit voltage measurement | Range: 0 to 1kV DC Accuracy: 0.25% of full scale |
Current measurement | Range: 0 to 20mA DC. Accuracy: 0.25% of full scale |
LEAKAGE: RESISTIVE LOADS FOR LEAKAGE CURRENT |
---|
Nominal Leakage Currents | At 230V AC of 0.5, 1, 2, 5, 10, 15mA |
Mains voltage measurement | Range: 0 to 500V AC Accuracy 0.25% of full scale |
Leakage current measurement | Range: 0 to 20mA AC Accuracy 0.25% of full scale |
TOUCH LEAKAGE: CONSTANT CURRENT SOURCE FOR TOUCH LEAKAGE METERS |
---|
Current | 1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance |
Current measurement | Range: 0 to 2mA AC. Accuracy: 0.25% of full scale |
LOAD TEST: CONNECTION OF EXTERNAL LOAD VIA AN IEC CONNECTOR |
---|
Mains voltage measurement | Range: 0 to 500V AC Accuracy: 0.25% of full scale |
Load current measurement | Range: 0 to 13A AC Accuracy: 0.5% of full scale |
Power | Internal battery 6V re-chargeable NiCad, >200 hrs between charges. |
Dimensions | W406 x H175 x D330mm |
Weight | 5.5kg |
Supplied With | 4mm terminal box adaptor, 110V adaptor, IEC connector (for external load), battery charger, and user manual. |
Optional Extras | Calibration certificates traceable NPL and UKAS |
Country of Origin | UK |
- Açıklama
Product Description:
A precision calibrator designed to provide rapid high accuracy calibration of portable appliance testers and insulation/continuity testers.
The 5080 PAT calibrator has functions for earth bond, insulation, leakage, touch leakage, and load test.Housed in a robust safety case the 5080 is easily portable and ideal for field calibration work. It is battery powered, which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current.
The 5080 is a dedicated solution for PAT testers and part of the electrical testing calibration range from Time Electronics. Other models include the 5030 electrical tester calibrator for RCD, loop, insulation, earth testers and multifunction installation testers. For insulation testers the 5069 InsCal is a portable instrument with resistance up to 100GOhm, and 10kV operation.
Technical Specification:
EARTH BOND: CALIBRATED LOW VALUE RESISTIVE LOADS Values / Accuracy 20mΩ, accuracy 5%
190mΩ, 210mΩ, 950mΩ, 1.050mΩ, 1.08Ω, 2Ω, 10Ω, 18Ω, accuracy 1%Open circuit voltage measurement Range: 0 to 20V
Accuracy: 0.25% of full scaleHigh current AC measurement Range: 0 to 50A AC
Accuracy: 0.5% of reading +/- 0.2ALow current AC measurement Range: 0 to 2A AC
Accuracy: 0.5% of reading +/- 2mALow current DC measurement Range: 0 to 2A DC
Accuracy: 1% of reading +/- 2mAINSULATION: CALIBRATED HIGH VALUE RESISTIVE LOADS Values / Accuracy 95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ, accuracy 0.1%
20MΩ, 50MΩ, 100MΩ, accuracy 1.0%Open circuit voltage measurement Range: 0 to 1kV DC
Accuracy: 0.25% of full scaleCurrent measurement Range: 0 to 20mA DC. Accuracy: 0.25% of full scale LEAKAGE: RESISTIVE LOADS FOR LEAKAGE CURRENT Nominal Leakage Currents At 230V AC of 0.5, 1, 2, 5, 10, 15mA Mains voltage measurement Range: 0 to 500V AC
Accuracy 0.25% of full scaleLeakage current measurement Range: 0 to 20mA AC
Accuracy 0.25% of full scaleTOUCH LEAKAGE: CONSTANT CURRENT SOURCE FOR TOUCH LEAKAGE METERS Current 1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance Current measurement Range: 0 to 2mA AC. Accuracy: 0.25% of full scale LOAD TEST: CONNECTION OF EXTERNAL LOAD VIA AN IEC CONNECTOR Mains voltage measurement Range: 0 to 500V AC
Accuracy: 0.25% of full scaleLoad current measurement Range: 0 to 13A AC
Accuracy: 0.5% of full scalePower Internal battery 6V re-chargeable NiCad, >200 hrs between charges. Dimensions W406 x H175 x D330mm Weight 5.5kg Supplied With 4mm terminal box adaptor, 110V adaptor, IEC connector (for external load), battery charger, and user manual. Optional Extras Calibration certificates traceable NPL and UKAS Country of Origin UK