5070 Ductor Tester and Micro-Ohmmeter Calibrator
5070 Ductor Tester and Micro-Ohmmeter Calibrator
0.00

Product Description:

The 5070 DuctorCal is a portable instrument suitable for calibrating high current ductor testers and micro-ohm meters. It incorporates 5 sets of high current standard resistors that are used to enable precision calibration.

It has full 4 terminal capabilities with extra large terminals for the current connection. Gold plated terminals are used throughout to reduce contact resistance and thermal emfs. It has a substantial maximum continuous current rating, but can also be used with much higher transient/pulse test currents. The internal resistance standards are all high quality manganin types with good long term stability and temperature coefficients.

Rugged and portable, the 5070 is ideal for site calibration work, housed in a safety yellow field case with carry handle.

Technical Specification:

RANGE CURRENT ACCURACY
50, 100, 150, 200μΩ 200A 0.8%
0.5, 1, 1.5, 2mΩ 100A 0.5%
5, 10, 15, 20mΩ 30A 0.2%
50, 100, 150, 200mΩ 10A 0.1%
0.5, 1, 1.5, 2Ω 3A 0.1%

The currents shown are the continuous rated currents for both AC and DC. Higher currents (as generated by pulse driven instruments) can be used, and with an ON to OFF time ratio of 1:10 or less the allowed peak currents are 10 times those specified above, with an upper limit of 1000A.
It is important to ensure there are adequate low resistance connections to the DuctorCal’s current terminals.

Dimensions W540 x H210 x D410mm
Weight 11kg
Optional Extras Calibration certificates traceable to NPL and UKAS
Country of Origin UK
  • Açıklama
    • Product Description:

      The 5070 DuctorCal is a portable instrument suitable for calibrating high current ductor testers and micro-ohm meters. It incorporates 5 sets of high current standard resistors that are used to enable precision calibration.

      It has full 4 terminal capabilities with extra large terminals for the current connection. Gold plated terminals are used throughout to reduce contact resistance and thermal emfs. It has a substantial maximum continuous current rating, but can also be used with much higher transient/pulse test currents. The internal resistance standards are all high quality manganin types with good long term stability and temperature coefficients.

      Rugged and portable, the 5070 is ideal for site calibration work, housed in a safety yellow field case with carry handle.

      Technical Specification:

      RANGE CURRENT ACCURACY
      50, 100, 150, 200μΩ 200A 0.8%
      0.5, 1, 1.5, 2mΩ 100A 0.5%
      5, 10, 15, 20mΩ 30A 0.2%
      50, 100, 150, 200mΩ 10A 0.1%
      0.5, 1, 1.5, 2Ω 3A 0.1%

      The currents shown are the continuous rated currents for both AC and DC. Higher currents (as generated by pulse driven instruments) can be used, and with an ON to OFF time ratio of 1:10 or less the allowed peak currents are 10 times those specified above, with an upper limit of 1000A.
      It is important to ensure there are adequate low resistance connections to the DuctorCal’s current terminals.

      Dimensions W540 x H210 x D410mm
      Weight 11kg
      Optional Extras Calibration certificates traceable to NPL and UKAS
      Country of Origin UK