Product Description:
The 5065 is a high performance, versatile 6½ digit bench multimeter with 19 measurement functions.
Low cost, simple operation, stability, and high accuracy make the 5065 an ideal DMM for a variety of applications. In addition high speed means both the sampling rate and the data transfer rate can achieve 2000 readings per second.
The comprehensive range of features makes the 5065 suitable for test engineers, R&D, service, and calibration technicians. The durable construction with a protective rubber guard and carry handle allows convenient bench top use, and transportability.
The front panel features a two-line, colour-coded display for easy to read measurements and functions. Control is simple, with common functions selected from a single button press.
The 5065 measures AC/DC voltage, AC/DC current, 2/4 wire resistance, frequency, period, diode, continuity, thermocouples and RTD.
In addition to standard functions many other capabilities such as Min/Max, Ratio/% and Null are included. Memory functions with up to 2000 readings can be stored and recalled. Limit testing with an external output can be configured to signal pass or fail.
The USB interface enables connectivity to a PC. A basic setup and graphing application is supplied as standard. Add-in utilities for Microsoft Excel and Word allow simple data collection directly into a spreadsheet or document.
An optional 10 channel scanner card is available which allows multiple inputs to be measured. Further options are test lead sets, GPIB and RS232 interfaces, and an RTD probe adaptor.
Also available for precision measurement is the 5075 digital multimeter, with superior functionality and range coverage for up to 10kV and 30A. It offers 7.5 digit resolution and is suitable for laboratory calibration applications.
Calibration made easy
Connect the 5065 to a PC/Laptop installed with Time Electronics’ EasyCal software and automate the calibration process. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.
Technical Specification:
DC VOLTAGE | |||
---|---|---|---|
RANGE | RESOLUTION | INPUT RESISTANCE | ACCURACY |
100.0000mV | 0.1μV | > 10GΩ | 0.0050 + 0.0035 |
1.000000V | 1.0μV | > 10GΩ | 0.0040 + 0.0007 |
10.00000V | 10μV | > 10GΩ | 0.0035 + 0.0005 |
100.0000V | 100μV | 10MΩ | 0.0045 + 0.0006 |
1000.000V | 1μV | 10MΩ | 0.0045 + 0.0010 |
DC CURRENT | |||
---|---|---|---|
RANGE | RESOLUTION | SHUNT RESISTANCE | ACCURACY |
10.000000mA | 10nA | 5.1Ω | 0.05 + 0.02 |
100.00000mA | 100nA | 5.1Ω | 0.05 + 0.005 |
1.000000A | 1μA | 0.1Ω | 0.1 + 0.01 |
3.00000A | 10μA | 0.1Ω | 0.12 + 0.02 |
AC VOLTAGE | |||
---|---|---|---|
RANGE | RESOLUTION | FREQUENCY (HZ) | ACCURACY |
100.0000mV | 0.1μV | 3 to 5 5 to 10 10 to 20k 20 to 50k 50K to 100k 100K to 300k |
1.00 + 0.04 0.35 + 0.04 0.06 + 0.04 0.12 + 0.05 0.60 + 0.08 4.00 + 0.50 |
1.000000V to 750.000V |
1.0μV to 1mV | 3 to 5 5 to 10 10 to 20k 20 to 50k 50K to 100k 100K to 300k |
1.00 + 0.03 0.35 + 0.03 0.06 + 0.03 0.12 + 0.05 0.60 + 0.08 4.00 + 0.50 |
AC CURRENT | |||
---|---|---|---|
RANGE | RESOLUTION | FREQUENCY (HZ) | ACCURACY |
1.000000A | 1μA | 3 to 5 5 to 10 10 to 5k |
1.00 + 0.04 0.30 + 0.04 0.10 + 0.04 |
3.000000 | 10μA | 3 to 5 5 to 10 10 to 5k |
1.10 + 0.06 0.35 + 0.06 0.15 + 0.06 |
RESISTANCE | |||
---|---|---|---|
RANGE | RESOLUTION | TEST CURRENT | ACCURACY |
100.0000Ω | 100μΩ | 1mA | 0.01 + 0.004 |
1.000000kΩ | 1mΩ | 1mA | 0.01 + 0.001 |
10.00000kΩ | 10mΩ | 100μA | 0.01 + 0.001 |
100.0000kΩ | 100mΩ | 10μA | 0.01 + 0.001 |
1.000000MΩ | 1Ω | 5μA | 0.01 + 0.001 |
10.00000MΩ | 10Ω | 500nA | 0.04 + 0.001 |
100.0000MΩ | 100Ω | 500nA | 0.8 + 0.01 |
Diode Test 1.0000V |
10μV | 1mA | 0.01 + 0.02 |
Continuity 1000.00KΩ |
10mΩ | 1mA | 0.01 + 0.03 |
FREQUENCY AND PERIOD | ||
---|---|---|
RANGE | FREQUENCY (HZ) | ACCURACY (% OF READING) |
100mV to 750V | 3 to 5 5 to 10 10 to 40 40 to 300k |
0.1 0.05 0.03 0.06 |
TEMPERATURE | |
---|---|
RTD Types | PT100, D100, F100, PT385 or PT3916. (Best Accuracy ±0.08°C ) |
Thermocouple Types | J, K & T (Accuracy ±0.5°C ). E (Accuracy ±0.6°C ). R, S & B (Accuracy ±5°C ) |
Standard Interfaces | RS-232 and USB (GPIB optional) |
Line Power | 100 – 230V AC 50/60Hz |
Dimensions | W210 x H85 x D350mm |
Weight | 4.4kg |
- Açıklama
Product Description:
The 5065 is a high performance, versatile 6½ digit bench multimeter with 19 measurement functions.
Low cost, simple operation, stability, and high accuracy make the 5065 an ideal DMM for a variety of applications. In addition high speed means both the sampling rate and the data transfer rate can achieve 2000 readings per second.The comprehensive range of features makes the 5065 suitable for test engineers, R&D, service, and calibration technicians. The durable construction with a protective rubber guard and carry handle allows convenient bench top use, and transportability.
The front panel features a two-line, colour-coded display for easy to read measurements and functions. Control is simple, with common functions selected from a single button press.
The 5065 measures AC/DC voltage, AC/DC current, 2/4 wire resistance, frequency, period, diode, continuity, thermocouples and RTD.
In addition to standard functions many other capabilities such as Min/Max, Ratio/% and Null are included. Memory functions with up to 2000 readings can be stored and recalled. Limit testing with an external output can be configured to signal pass or fail.
The USB interface enables connectivity to a PC. A basic setup and graphing application is supplied as standard. Add-in utilities for Microsoft Excel and Word allow simple data collection directly into a spreadsheet or document.
An optional 10 channel scanner card is available which allows multiple inputs to be measured. Further options are test lead sets, GPIB and RS232 interfaces, and an RTD probe adaptor.
Also available for precision measurement is the 5075 digital multimeter, with superior functionality and range coverage for up to 10kV and 30A. It offers 7.5 digit resolution and is suitable for laboratory calibration applications.
Calibration made easy
Connect the 5065 to a PC/Laptop installed with Time Electronics’ EasyCal software and automate the calibration process. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.Technical Specification:
DC VOLTAGE RANGE RESOLUTION INPUT RESISTANCE ACCURACY 100.0000mV 0.1μV > 10GΩ 0.0050 + 0.0035 1.000000V 1.0μV > 10GΩ 0.0040 + 0.0007 10.00000V 10μV > 10GΩ 0.0035 + 0.0005 100.0000V 100μV 10MΩ 0.0045 + 0.0006 1000.000V 1μV 10MΩ 0.0045 + 0.0010 DC CURRENT RANGE RESOLUTION SHUNT RESISTANCE ACCURACY 10.000000mA 10nA 5.1Ω 0.05 + 0.02 100.00000mA 100nA 5.1Ω 0.05 + 0.005 1.000000A 1μA 0.1Ω 0.1 + 0.01 3.00000A 10μA 0.1Ω 0.12 + 0.02 AC VOLTAGE RANGE RESOLUTION FREQUENCY (HZ) ACCURACY 100.0000mV 0.1μV 3 to 5
5 to 10
10 to 20k
20 to 50k
50K to 100k
100K to 300k1.00 + 0.04
0.35 + 0.04
0.06 + 0.04
0.12 + 0.05
0.60 + 0.08
4.00 + 0.501.000000V
to
750.000V1.0μV to 1mV 3 to 5
5 to 10
10 to 20k
20 to 50k
50K to 100k
100K to 300k1.00 + 0.03
0.35 + 0.03
0.06 + 0.03
0.12 + 0.05
0.60 + 0.08
4.00 + 0.50AC CURRENT RANGE RESOLUTION FREQUENCY (HZ) ACCURACY 1.000000A 1μA 3 to 5
5 to 10
10 to 5k1.00 + 0.04
0.30 + 0.04
0.10 + 0.043.000000 10μA 3 to 5
5 to 10
10 to 5k1.10 + 0.06
0.35 + 0.06
0.15 + 0.06RESISTANCE RANGE RESOLUTION TEST CURRENT ACCURACY 100.0000Ω 100μΩ 1mA 0.01 + 0.004 1.000000kΩ 1mΩ 1mA 0.01 + 0.001 10.00000kΩ 10mΩ 100μA 0.01 + 0.001 100.0000kΩ 100mΩ 10μA 0.01 + 0.001 1.000000MΩ 1Ω 5μA 0.01 + 0.001 10.00000MΩ 10Ω 500nA 0.04 + 0.001 100.0000MΩ 100Ω 500nA 0.8 + 0.01 Diode Test
1.0000V10μV 1mA 0.01 + 0.02 Continuity
1000.00KΩ10mΩ 1mA 0.01 + 0.03 FREQUENCY AND PERIOD RANGE FREQUENCY (HZ) ACCURACY (% OF READING) 100mV to 750V 3 to 5
5 to 10
10 to 40
40 to 300k0.1
0.05
0.03
0.06TEMPERATURE RTD Types PT100, D100, F100, PT385 or PT3916. (Best Accuracy ±0.08°C ) Thermocouple Types J, K & T (Accuracy ±0.5°C ). E (Accuracy ±0.6°C ). R, S & B (Accuracy ±5°C ) Standard Interfaces RS-232 and USB (GPIB optional) Line Power 100 – 230V AC 50/60Hz Dimensions W210 x H85 x D350mm Weight 4.4kg