5011 Resistance
362514
5011 Resistance and Temperature Calibrator
5011 Resistance and Temperature Calibrator
0.00

Product Description:

The 5011 is a versatile, high accuracy calibrator that can be used in a wide range of applications across various industries. Primarily used as a programmable resistance / RTD source, the 5011 provides precision resistance with a best accuracy of 0.01% and 1mΩ resolution (50Ω to 1kΩ).

Internal options for increased capabilities can be fitted as per customer requirement. These include DC voltage and thermocouple simulation, DC current, and frequency. The 5011 can be used as a laboratory grade resistance and temperature calibrator, or incorporated into an automated test system for dedicated signal injections. A rack mount kit option is also available.

Simple Operation and Clear Visual Display
Front panel operation allows the user to quickly set the function and output required. Using the jog / shuttle dial deviation the user can finely adjust the output value as a percentage (+/- 9.99%). All this information is shown on an easy to read LED display. 

As standard the 5011 uses a SCPI command structure for programming. It also supports the Time Electronics 9811/19/20 command set making it an ideal replacement for these legacy models.

Flexible Options
A range of internally fitted options are available for the 5011, providing added functionality and features. The DCV / Thermocouple option provides a DC voltage source (+/- 20V) and simulates thermocouple types K, J, T, R, S, N, E and B. With the DC current option fitted the 5011 can source up to 220mA. This makes the instrument ideal for accurate process control calibration. Also available is a 0.1Hz to 10MHz frequency option (Period 100ns to 10s). The output is variable with a best resolution setting of 0.1Hz.

EasyCal Software – Manage, Automate and Optimise the Calibration Process
Connect the 5011 to a PC/Laptop (via RS-232, GPIB, or USB) installed with EasyCal software and automate the calibration process. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.

Technical Specification:

 
RESISTANCE
RANGE ACCURACY RESOLUTION
1Ω to 20Ω 0.01% +/- 5mΩ
20Ω to 99.999Ω 0.01% +/- 5mΩ 1mΩ/5mΩ*
100Ω to 999.999Ω 0.01% +/- 5mΩ 1mΩ
1kΩ to 9.999kΩ 0.02% +/- 20mΩ
10kΩ to 99.999kΩ 0.01% +/- 1Ω
100kΩ to 999.99kΩ 0.01% +/- 10Ω 10Ω
1MΩ to 9.9999MΩ 0.02% +/- 100Ω 100Ω
10MΩ to 120MΩ 0.1% +/- 1kΩ 1kΩ

* Output Setting Resolution below 50Ω is 5mΩ

Temperature Coefficient Less than 50ppm per °C
Power Rating 0.1 Watt per resistor
Maximum Voltage 250V
Resistance Switch Time < 250μs
Operation Time < 300ms
End Resistance Variation < 2.5mΩ
 

PRT

SIMULATION
RTD TYPE ALPHA COEFFICIENT RANGE ACCURACY
PT100 0.003850 -180 to -100°C 0.1°C
PT100 0.003850 -100 to 850°C 0.05°C

It should be noted that the accuracy of the PRT simulation is determined by the accuracy of the PRT tables (BS EN 60751) published by the British Standards Institute. The 5011 uses precise digital interpretation of the tables to output resistance values that are within the accuracies specified in the table.

 

Thermocouple Simulation

(9711)
TYPE RANGE °C ACCURACY °C
J -210 to 150 / 150 to 1200 0.15 / 0.3
K -270 to 190 / 190 to 1250 0.5 / 0.6
T -200 to 150 / 150 to 400 0.4 / 0.5
R -50 to 800 / 800 to 1750 0.8 / 2.0
S -50 to 850 / 850 to 1750 0.9 / 2.0
B 100 to 1200 / 1200 to 1800 1.0 / 2.0
N -270 to 260 / 260 to 1300 0.5 / 0.4
E -50 to 1000 0.3

Cold Junction Compensation +/- 0.5°C (applies to ambient changes of less than +/- 1°C at 23°C).
The accuracy of the thermocouple simulation is determined by the accuracy of the 5011’s DC voltage function and the accuracy of the standard thermocouple tables (BS EN 60584-1) published by the British Standards Institute. The 5011 uses precise digital interpretation of the tables to output voltage levels that are within the accuracies specified in the table.

 

DC Voltage*

(9711)
RANGE ACCURACY RESOLUTION
20mV 100ppm + 4μV 100nV
200mV 30ppm + 6μV 1μV
2V 25ppm + 20μV 1μV
20V 25ppm + 150μV 10μV

* Specifications apply from 10 to 100% of range. 10% over range.

 

DC Current* (9718, requires 9711 option to be fitted also) Compliance Voltage:

11V
RANGE ACCURACY RESOLUTION
200μA 150ppm + 15nA 1nA
2mA 100ppm + 40nA 10nA
20mA 80ppm + 200nA 10nA
200mA 80ppm + 3μA 100nA

* Specifications apply from 10 to 100% of range. 10% over range.

 

Digital Frequency / Period (9729): 2V pk/pk

APPROX
Range 0.1Hz to 10MHz / 100ns to 10s
Accuracy 20ppm
Warm up 30 minutes to full accuracy
Settling Time Less than 5 seconds
Standard Interfaces GPIB (IEEE-488), RS-232, USB
Temp Performance Operating: 0 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C
Operating Humidity < 80% non-condensing
Operating Altitude 0 to 3km. Non operating: 3km to 12km
Line Power 100 – 230V AC 50/60Hz. Power Consumption 60W typical, 80W Max.
Dimensions W450 x D272 x H152mm (18 x 11 x 7”)
Weight 7kg (15.4lbs)
Country of Origin UK
Supplied With User manual, RS-232 cable, and USB adaptor/cable
  • Açıklama
    • Product Description:

      The 5011 is a versatile, high accuracy calibrator that can be used in a wide range of applications across various industries. Primarily used as a programmable resistance / RTD source, the 5011 provides precision resistance with a best accuracy of 0.01% and 1mΩ resolution (50Ω to 1kΩ).

      Internal options for increased capabilities can be fitted as per customer requirement. These include DC voltage and thermocouple simulation, DC current, and frequency. The 5011 can be used as a laboratory grade resistance and temperature calibrator, or incorporated into an automated test system for dedicated signal injections. A rack mount kit option is also available.

      Simple Operation and Clear Visual Display
      Front panel operation allows the user to quickly set the function and output required. Using the jog / shuttle dial deviation the user can finely adjust the output value as a percentage (+/- 9.99%). All this information is shown on an easy to read LED display. 

      As standard the 5011 uses a SCPI command structure for programming. It also supports the Time Electronics 9811/19/20 command set making it an ideal replacement for these legacy models.

      Flexible Options
      A range of internally fitted options are available for the 5011, providing added functionality and features. The DCV / Thermocouple option provides a DC voltage source (+/- 20V) and simulates thermocouple types K, J, T, R, S, N, E and B. With the DC current option fitted the 5011 can source up to 220mA. This makes the instrument ideal for accurate process control calibration. Also available is a 0.1Hz to 10MHz frequency option (Period 100ns to 10s). The output is variable with a best resolution setting of 0.1Hz.

      EasyCal Software – Manage, Automate and Optimise the Calibration Process
      Connect the 5011 to a PC/Laptop (via RS-232, GPIB, or USB) installed with EasyCal software and automate the calibration process. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.

      Technical Specification:

       
      RESISTANCE
      RANGE ACCURACY RESOLUTION
      1Ω to 20Ω 0.01% +/- 5mΩ
      20Ω to 99.999Ω 0.01% +/- 5mΩ 1mΩ/5mΩ*
      100Ω to 999.999Ω 0.01% +/- 5mΩ 1mΩ
      1kΩ to 9.999kΩ 0.02% +/- 20mΩ
      10kΩ to 99.999kΩ 0.01% +/- 1Ω
      100kΩ to 999.99kΩ 0.01% +/- 10Ω 10Ω
      1MΩ to 9.9999MΩ 0.02% +/- 100Ω 100Ω
      10MΩ to 120MΩ 0.1% +/- 1kΩ 1kΩ

      * Output Setting Resolution below 50Ω is 5mΩ

      Temperature Coefficient Less than 50ppm per °C
      Power Rating 0.1 Watt per resistor
      Maximum Voltage 250V
      Resistance Switch Time < 250μs
      Operation Time < 300ms
      End Resistance Variation < 2.5mΩ
       

      PRT

      SIMULATION
      RTD TYPE ALPHA COEFFICIENT RANGE ACCURACY
      PT100 0.003850 -180 to -100°C 0.1°C
      PT100 0.003850 -100 to 850°C 0.05°C

      It should be noted that the accuracy of the PRT simulation is determined by the accuracy of the PRT tables (BS EN 60751) published by the British Standards Institute. The 5011 uses precise digital interpretation of the tables to output resistance values that are within the accuracies specified in the table.

       

      Thermocouple Simulation

      (9711)
      TYPE RANGE °C ACCURACY °C
      J -210 to 150 / 150 to 1200 0.15 / 0.3
      K -270 to 190 / 190 to 1250 0.5 / 0.6
      T -200 to 150 / 150 to 400 0.4 / 0.5
      R -50 to 800 / 800 to 1750 0.8 / 2.0
      S -50 to 850 / 850 to 1750 0.9 / 2.0
      B 100 to 1200 / 1200 to 1800 1.0 / 2.0
      N -270 to 260 / 260 to 1300 0.5 / 0.4
      E -50 to 1000 0.3

      Cold Junction Compensation +/- 0.5°C (applies to ambient changes of less than +/- 1°C at 23°C).
      The accuracy of the thermocouple simulation is determined by the accuracy of the 5011’s DC voltage function and the accuracy of the standard thermocouple tables (BS EN 60584-1) published by the British Standards Institute. The 5011 uses precise digital interpretation of the tables to output voltage levels that are within the accuracies specified in the table.

       

      DC Voltage*

      (9711)
      RANGE ACCURACY RESOLUTION
      20mV 100ppm + 4μV 100nV
      200mV 30ppm + 6μV 1μV
      2V 25ppm + 20μV 1μV
      20V 25ppm + 150μV 10μV

      * Specifications apply from 10 to 100% of range. 10% over range.

       

      DC Current* (9718, requires 9711 option to be fitted also) Compliance Voltage:

      11V
      RANGE ACCURACY RESOLUTION
      200μA 150ppm + 15nA 1nA
      2mA 100ppm + 40nA 10nA
      20mA 80ppm + 200nA 10nA
      200mA 80ppm + 3μA 100nA

      * Specifications apply from 10 to 100% of range. 10% over range.

       

      Digital Frequency / Period (9729): 2V pk/pk

      APPROX
      Range 0.1Hz to 10MHz / 100ns to 10s
      Accuracy 20ppm
      Warm up 30 minutes to full accuracy
      Settling Time Less than 5 seconds
      Standard Interfaces GPIB (IEEE-488), RS-232, USB
      Temp Performance Operating: 0 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C
      Operating Humidity < 80% non-condensing
      Operating Altitude 0 to 3km. Non operating: 3km to 12km
      Line Power 100 – 230V AC 50/60Hz. Power Consumption 60W typical, 80W Max.
      Dimensions W450 x D272 x H152mm (18 x 11 x 7”)
      Weight 7kg (15.4lbs)
      Country of Origin UK
      Supplied With User manual, RS-232 cable, and USB adaptor/cable