1090 Portable
362235
1090 Portable Process Calibrator
1090 Portable Process Calibrator
0.00

Product Description:

The 1090 is a precision portable process calibrator that combines source and measurement functions for thermocouples, PT100s, µV, mV & mA.
As a multifunction instrument the 1090 combines accuracy and durability with simple operation, making it ideal for process plant applications.
Thermocouple Measurement and Simulation
Measure and simulate the temperature and mV characteristics of J, K, T, R, S, B, N and E thermocouples.

Cold Junction Compensation
The unit can be operated with or without internal cold junction compensation. 

PT100 Measurement and Simulation
Based on 0.3850 alpha probe standard. Range is -200°C to 700°C.

Measurement and Source (µV, mV, and mA)
Measurement ranges are 0 to +/-30mV and 0 to +/-60mA. Source ranges are 0 to +/-80mV and 0 to +80mA.

Temperature Units Selection
The display can be easily changed from °C to °F. The equivalent uV (thermocouples) and ohms (PT100) can also be shown.

24V Process Loop Drive Mode
A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source’ mode and setting it at 60mA (or a lower level if required).

Inching (Incrementing/Decrementing)
The unit has a general-purpose inching function. This adjusts the output in fixed increments of temperature (thermocouples only) or voltage or current. The set-up menu gives a the user a choice of three levels of increment i.e. 0.1, 1 or 10 for °C/°F, or 1, 10, or 100 uV/uA for voltage/current. The lowest of these represents the highest setting resolution and provides the most precise control of the output.  This is especially useful for calibrating thermostat controllers that have tight specification on hysteresis.

Memory Recall and Step/Auto-Step Functions
Up to 10 values can be stored in the unit’s non-volatile memory and they can be recalled at any time. The user can also manually step through them in sequence using the step key. Continuous stepping (auto-step) is also available at any user selectable rate between 1 & 10 seconds/step.

Power is via an internal high capacity rechargeable metal hydride battery that can be recharged from the supplied external mains charger. An auto power-down feature helps conserve battery life by switching off the instrument if inactive for over 5 minutes. This feature can be disabled if not required. The unit is supplied in a robust case with a carrying strap. A pocket for the instruction manual is provided.

Product Specification:

TEMPERATURE MEASURE
THERMOCOUPLE TYPE TEMPERATURE RANGE (°C) ACCURACY (°C)
J -200 to 580 0.7
K -200 to -150
-150 to 750
2.5
0.5
T -200 to 0
0 to 400
1.5
0.4
R 50 to 400
400 to 1750
3.0
1.5
S -50 to 100
100 to 1750
3.0
1.5
B 110 to 1000
1000 to 1800
3.5
1.5
N -100 to 890 0.6
E -50 to 400 0.4
     
Resolution 0.1°C or 0.1°F  
 
TEMPERATURE SIMULATION
THERMOCOUPLE TYPE TEMPERATURE RANGE (°C) ACCURACY (°C)
J -210 to 150
150 to 1200
0.15
0.3
K -270 to 190
190 to 1250
0.5
0.4
T -200 to 150
150 to 400
0.4
0.5
R -50 to 800
800 to 1750
0.8
2.0
S -50 to 850
850 to 1750
0.9
2.0
B 100 to 1200
1200 to 1800
2.0
3.0
N -270 to 260
260 to 1300
0.5
1.0
E -50 to 1000 0.3
     
Resolution 0.1°C or 0.1°F  

Note: An additional correction representing the equivalent 1μV should be allowed for stray thermal emf effects (Temperature measure & simulation).

 
PT100 SIMULATION
14 SET TEMPERATURE POINTS (°C) ACCURACY
-100, -50, -20, 0, 20, 50, 100, 200, 300, 400, 500, 600, 700, 800 0.1% of resistance value (typically 0.5 °C)
 
PT100 MEASURE
RANGE ACCURACY RESOLUTION
200 to 700 °C, 2 wire. 0.2% of resistance value (typically 0.7 °C) 0.2°C (or 0.2°F)
 
MILLIVOLT MEASURE
RANGE RESOLUTION ACCURACY INPUT RESISTANCE
0 to +/- 30mV 10μV 0.05% of full scale ±1 digit 100kΩ
 
MILLIVOLT SOURCE
RANGE RESOLUTION ACCURACY OUTPUT RESISTANCE
0 to 8mV 0.5μV +/- 4μV 10Ω
8 to 80mV 5μV 0.02% of full scale 10Ω
 
MILLIAMP MEASURE
RANGE RESOLUTION ACCURACY INPUT RESISTANCE
0 to 60mA 20μA 0.05% of full scale ±1 digit 0.5Ω
 
MILLIAMP SOURCE
RANGE RESOLUTION ACCURACY
0 to 8mA 0.5μA +/-10μA
8 to 80mA 5μA 0.02% of full scale
 
FURTHER FEATURES AND FUNCTIONS
Inching Three levels of increment, 0.1, 1 or 10 for °C/°F, and 1, 10, or 100 μV/ μA for voltage/current. The lowest of these represents the highest setting resolution and provides the most precise control of the output.
24V Process Loop Drive A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source’ mode and setting it at 60mA
(or a lower level if required). Max Load Specifications: 300Ω/80mA, 480Ω/50mA, 1.2kΩ/20mA
Memory recall & step 10 memory locations for non-volatile storage of values. Manual & AutoStep, rate adjustable from 1 to 10 sec/step
Cold Junction Compensation Accuracy 0.2°C. Resolution 0.1°C.
Operating Temperature -10 to 40°C (15 to 105°F)
Connections Industry standard 4mm screw terminals
Power A Ni-MH rechargeable battery pack gives approx. 60 hours continuous use. The mains recharger supplied gives full recharge in 11 hours. To conserve battery life a user inactivity power-down feature is included.
Dimensions H235 x W150 x D75mm
Weight 1.2kg
Supplied With Carry case, rechargeable battery pack (installed) with mains charger, and user manual
Optional Extras Calibration certificates traceable NPL and UKAS
Country of Origin UK
  • Açıklama
    • Product Description:

      The 1090 is a precision portable process calibrator that combines source and measurement functions for thermocouples, PT100s, µV, mV & mA.
      As a multifunction instrument the 1090 combines accuracy and durability with simple operation, making it ideal for process plant applications.
      Thermocouple Measurement and Simulation
      Measure and simulate the temperature and mV characteristics of J, K, T, R, S, B, N and E thermocouples.

      Cold Junction Compensation
      The unit can be operated with or without internal cold junction compensation. 

      PT100 Measurement and Simulation
      Based on 0.3850 alpha probe standard. Range is -200°C to 700°C.

      Measurement and Source (µV, mV, and mA)
      Measurement ranges are 0 to +/-30mV and 0 to +/-60mA. Source ranges are 0 to +/-80mV and 0 to +80mA.

      Temperature Units Selection
      The display can be easily changed from °C to °F. The equivalent uV (thermocouples) and ohms (PT100) can also be shown.

      24V Process Loop Drive Mode
      A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source’ mode and setting it at 60mA (or a lower level if required).

      Inching (Incrementing/Decrementing)
      The unit has a general-purpose inching function. This adjusts the output in fixed increments of temperature (thermocouples only) or voltage or current. The set-up menu gives a the user a choice of three levels of increment i.e. 0.1, 1 or 10 for °C/°F, or 1, 10, or 100 uV/uA for voltage/current. The lowest of these represents the highest setting resolution and provides the most precise control of the output.  This is especially useful for calibrating thermostat controllers that have tight specification on hysteresis.

      Memory Recall and Step/Auto-Step Functions
      Up to 10 values can be stored in the unit’s non-volatile memory and they can be recalled at any time. The user can also manually step through them in sequence using the step key. Continuous stepping (auto-step) is also available at any user selectable rate between 1 & 10 seconds/step.

      Power is via an internal high capacity rechargeable metal hydride battery that can be recharged from the supplied external mains charger. An auto power-down feature helps conserve battery life by switching off the instrument if inactive for over 5 minutes. This feature can be disabled if not required. The unit is supplied in a robust case with a carrying strap. A pocket for the instruction manual is provided.

      Product Specification:

      TEMPERATURE MEASURE
      THERMOCOUPLE TYPE TEMPERATURE RANGE (°C) ACCURACY (°C)
      J -200 to 580 0.7
      K -200 to -150
      -150 to 750
      2.5
      0.5
      T -200 to 0
      0 to 400
      1.5
      0.4
      R 50 to 400
      400 to 1750
      3.0
      1.5
      S -50 to 100
      100 to 1750
      3.0
      1.5
      B 110 to 1000
      1000 to 1800
      3.5
      1.5
      N -100 to 890 0.6
      E -50 to 400 0.4
           
      Resolution 0.1°C or 0.1°F  
       
      TEMPERATURE SIMULATION
      THERMOCOUPLE TYPE TEMPERATURE RANGE (°C) ACCURACY (°C)
      J -210 to 150
      150 to 1200
      0.15
      0.3
      K -270 to 190
      190 to 1250
      0.5
      0.4
      T -200 to 150
      150 to 400
      0.4
      0.5
      R -50 to 800
      800 to 1750
      0.8
      2.0
      S -50 to 850
      850 to 1750
      0.9
      2.0
      B 100 to 1200
      1200 to 1800
      2.0
      3.0
      N -270 to 260
      260 to 1300
      0.5
      1.0
      E -50 to 1000 0.3
           
      Resolution 0.1°C or 0.1°F  

      Note: An additional correction representing the equivalent 1μV should be allowed for stray thermal emf effects (Temperature measure & simulation).

       
      PT100 SIMULATION
      14 SET TEMPERATURE POINTS (°C) ACCURACY
      -100, -50, -20, 0, 20, 50, 100, 200, 300, 400, 500, 600, 700, 800 0.1% of resistance value (typically 0.5 °C)
       
      PT100 MEASURE
      RANGE ACCURACY RESOLUTION
      200 to 700 °C, 2 wire. 0.2% of resistance value (typically 0.7 °C) 0.2°C (or 0.2°F)
       
      MILLIVOLT MEASURE
      RANGE RESOLUTION ACCURACY INPUT RESISTANCE
      0 to +/- 30mV 10μV 0.05% of full scale ±1 digit 100kΩ
       
      MILLIVOLT SOURCE
      RANGE RESOLUTION ACCURACY OUTPUT RESISTANCE
      0 to 8mV 0.5μV +/- 4μV 10Ω
      8 to 80mV 5μV 0.02% of full scale 10Ω
       
      MILLIAMP MEASURE
      RANGE RESOLUTION ACCURACY INPUT RESISTANCE
      0 to 60mA 20μA 0.05% of full scale ±1 digit 0.5Ω
       
      MILLIAMP SOURCE
      RANGE RESOLUTION ACCURACY
      0 to 8mA 0.5μA +/-10μA
      8 to 80mA 5μA 0.02% of full scale
       
      FURTHER FEATURES AND FUNCTIONS
      Inching Three levels of increment, 0.1, 1 or 10 for °C/°F, and 1, 10, or 100 μV/ μA for voltage/current. The lowest of these represents the highest setting resolution and provides the most precise control of the output.
      24V Process Loop Drive A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source’ mode and setting it at 60mA
      (or a lower level if required). Max Load Specifications: 300Ω/80mA, 480Ω/50mA, 1.2kΩ/20mA
      Memory recall & step 10 memory locations for non-volatile storage of values. Manual & AutoStep, rate adjustable from 1 to 10 sec/step
      Cold Junction Compensation Accuracy 0.2°C. Resolution 0.1°C.
      Operating Temperature -10 to 40°C (15 to 105°F)
      Connections Industry standard 4mm screw terminals
      Power A Ni-MH rechargeable battery pack gives approx. 60 hours continuous use. The mains recharger supplied gives full recharge in 11 hours. To conserve battery life a user inactivity power-down feature is included.
      Dimensions H235 x W150 x D75mm
      Weight 1.2kg
      Supplied With Carry case, rechargeable battery pack (installed) with mains charger, and user manual
      Optional Extras Calibration certificates traceable NPL and UKAS
      Country of Origin UK
Kapat